Send Message
Home ProductsDesiccant Air Dryers

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355

I'm Online Chat Now

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355
Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355

Large Image :  Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355

Product Details:
Place of Origin: China
Brand Name: Atlas
Certification: ISO 8573-1 CLASS 0
Model Number: CD50+-300+&CD60-355
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: be negotiated
Packaging Details: Atlas standard packing
Delivery Time: 7~30days
Payment Terms: L/C, T/T, D/A, Western Union, D/P
Supply Ability: 100pcs per month

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355

Description
Material: Aluminum Alloy Brand: Atlas
Maximum Working Pressure: 10 Bar Frequency: 50,60 Hz
Fad: 3.0-18 M³/min Drying Method: Desiccant Adsorption
Power Source: Electricity Model: CD50+-300+$CD60-355
Highlight:

Optimal Performance Desiccant Air Dryers

,

Innovative Design Desiccant Air Dryers

,

CD50+-300+ Desiccant Air Dryers

Atlas CD50+-300+/CD60-355 Twin Tower Adsorption Dryer

 

 

High reliability and high practicality

 

1.Unique valve body design
• Standard pressure dew point -40°C
• Standard pressure dew point -20°C (CD355)
• Optional pressure dew point -20°C
• Filling up to 30% extra adsorbent to ensure stable performance under extreme conditions such as high temperature and short-term overload

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 0

 

2.Stainless steel valve
• High performance all stainless steel butterfly valve ensures long life

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 1

 

3.Large size muffler with built-in safety valve

• Advanced muffler eliminates back pressure, increases purification efficiency,reduces exhaust noise, and built-in safety valve ensures continuous operation of the equipment in case of blockage

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 2

 

4.Galvanized flange connection pipe
• Flange connection is easy to maintain and reduces leakage
• Optimize pipe size to ensure low pressure drop and save energy

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 3

 

5.Filter (option)
• Pre-filter protects the adsorbent from oil contamination and prolongs the service life of the adsorbent
• Post-filter protects the pipe network from adsorbent dust particles and avoids pipe network contamination
• Allows direct installation at the air inlet and exhaust section of the dryer to reduce the pressure drop
• As no additional pipes and filter connection pipes are required, assembly and maintenance are very simple

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 4

 

6.Advanced control and detection system
• The control system is integrated in the IP54 control cabinet, which makes wiring simple and safe
• Monitors all parameters to ensure high-reliability installation

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 5

 

7.Pressure dew point control option
• Real-time pressure dew point monitoring (hygrometer)
• Pressure dew point displayed on controller (and alarm)
• Dryer switches to another drying tower when adsorbent is saturated
(with Electronics controller, based on pressure dew point)
• Standard for CD50+-300+, option for CD60-300

Innovative Design Desiccant Air Dryers for Optimal Performance CD50+-300+&CD60-355 6

 

8.Reliable design
• Standard structure includes forklift and lifting holes
• Large drying tower ensures low air velocity and longer contact time
• Integrated flange connections at the top and bottom of the drying tower shell to reduce the overall height

 

 

 

Technical Parameters:

Type Working Pressure Reference working condition flow pressure dew point(PDP)-40 Maximum temperature (ambient/air inlet) Pressure drop (without filter) Power Volt Deminsions Weiht Outlet
L W H
bar l/s m³/min bar kw mm mm mm kg flange
CD60-40 4~10 60 3.6 45/50 0.16 0.063 230V/1Ph/50Hz 867 739 1492 334 DN25
CD90-40 4-10 90 5.4 45/50 0.16 0.063 230V/1Ph/50Hz 1008 677 1742 427 DN40
CD130-40 4-10 130 7.8 45/50 0.16 0.063 230V/1Ph/50Hz 1062 677 1789 472 DN40
CD180-40 4~10 180 10.8 45/50 0.16 0.063 230V/1Ph/50Hz 1362 795 1826 587 DN40
CD220-40 4-10 220 13.2 45/50 0.16 0.063 230V/1Ph/50Hz 1417 795 1857 687 DN40
CD300-40 4~10 300 18.0 45/50 0.16 0.063 230V/1Ph/50Hz 1517 795 1899 760 DN50
CD355-20 4-10 355 21.3 45/50 0.25 0.063 230V/1Ph/50Hz 1351 807 2273 684 DN65
CD50+-40C 4-10 50 3.0 45/50 0.16 0.063 230V/1Ph/50Hz 867 650 1478 344 DN25
CD80+-40 4~10 80 4.8 45/50 0.16 0.063 230V/1Ph/50Hz 1008 677 1718 437 DN40
CD110+-40 4-10 110 6.6 45/50 0.16 0.063 230V/1Ph/50Hz 1062 677 1775 487 DN40
CD150+-40 4-10 150 9.0 45/50 0.16 0.063 230V/1Ph/50Hz 1362 795 1812 617 DN40
CD185+-40 4~10 185 11.1 45/50 0.16 0.063 230V/1Ph/50Hz 1417 795 1843 717 DN40
CD250+-40 4-10 250 15.0 45/50 0.16 0.063 230V/1Ph/50Hz 1470 795 1879 790 DN50
CD300+-40 4-10 300 18.0 45/50 0.16 0.063 230V/1Ph/50Hz 1517 700 1885 839 DN50

Contact Details
CEBE GROUP HK CO.,LTD

Contact Person: Mr. Kenny

Fax: 852--30771258

Send your inquiry directly to us (0 / 3000)